Chattanooga Intelect Focus Shockwave vs ELvation PiezoWave2T

Both the Chattanooga Intelect Focus Shockwave and the ELvation PiezoWave2T concentrate their energy at a focal point inside tissue, so they are built for the same clinical job and compare fairly. The Chattanooga Intelect Focus Shockwave uses electromagnetic wave generation; the ELvation PiezoWave2T uses piezoelectric. Only the Chattanooga Intelect Focus Shockwave has a published purchase figure ($50,176.02 estimate); the ELvation PiezoWave2T's price is not published. FDA records located: for the Chattanooga Intelect Focus Shockwave, an establishment listing only, which is not a clearance; for the ELvation PiezoWave2T, an establishment listing only, which is not a clearance.

Specs and prices are estimates based on publicly available data as of September 2026. Confirm details with the manufacturer or seller before you buy.

Side by side

SpecificationFocusedChattanooga Intelect Focus ShockwaveFocusedELvation PiezoWave2T
Technology
CategoryFocused systemsFocused systems
Wave generationElectromagneticPiezoelectricdirect focusing, no reflector
Energy fieldWhere the peak energy landsPeaks at a focal pointPeaks at a focal point
Technology as publishedElectromagnetic focusedFocused piezoelectric, direct focusing
Stated use or positioningNot statedAcoustic compression therapy for minor aches and painsthe US intended use, per ELvation
Energy outputPressure in bar, energy flux density in mJ/mm² and energy per pulse in mJ are different quantities. A figure in one row never stands in for another.
Energy flux densitymJ/mm²0.01–0.55 mJ/mm²Up to 0.82 mJ/mm²on ELvation's European therapy sources
Energy per pulsemJ1.7–8.5 mJwithin a 2.5 mm radius, from the operating manual's output tableNot published
FrequencyHz1–8 HzUp to 12 Hzcapped at 8 Hz at the highest intensities
Depth and treatment fieldFocal depth, penetration and focus volume measure three different things. Compare like with like.
Focal depth0–65 mmfocal zone, set with the two stand-offs20–60 mmfocal centre across the three US therapy sources
Maximum penetrationAwaiting manufacturer confirmationOur own catalogue states approximately 12 cm and Enovis states 12.5 cm. Neither figure is published until the manufacturer confirms which is current.0.5 mm to 6 cmdepending on the therapy source
Focus volumeA volume, not a depth5 × 5 × 30 mmfocus sizeNot published
Applicators and handpiece
Applicators and transmitters2 stand-off variationsF7G3, F10G10 and FBL10x5G2 therapy sourcesthe US line-up; a replacement F7G3 lists at $6,900
Handpiece life5 million shocksexpected; coil exchanged every 2 million5 million pulsesguaranteed per therapy source
Applicator weight590 gper the US product page; the US operating manual gives 990 gNot published
Size and setup
Unit weight22.1 kg (≈ 48.7 lb)control deviceNot published
Dimensions450 × 165 × 530 mmW × H × D405 × 226 × 450 mmUS control unit, W × H × D
ConfigurationTransportable console with an LCD touchscreenControl unit on a cartfoot switch; the US Starter package adds one therapy source and gel pads
Other published details100–240 VAC, up to 450 VAexpected service life of the control device: 15,000 operating hoursHigh-resolution touch screenT-Burst and T-Ramp modes; gel pads set the depth in 5 mm steps
Price and buying
Purchase price$50,176.02estimateNot publicly listed
Monthly lease$1,165 per monthestimateNot publicly listed
Priced accessoriesF-SW Cart, $1,252.22Not published
Warranty and guaranteesTwo years on the control devicenew handpieces covered up to 1 million pulses; the coil and wear parts are excludedOne yearF7G3 source one year or 3 million impulses; FBL source one year or 5 million; consumables 90 days
Sales and servicePurchase or lease through Shockwave SourceELvation Medical LLC, Alpharetta, Georgiaexclusive US seller; Richard Wolf assembles US units in Chicago
Regulatory recordRecord types and numbers exactly as located. A record covers one configuration and one indication, and never transfers to another product.
FDA record locatedEstablishment listing onlynot a model-specific clearanceEstablishment listing onlynot a model-specific clearance
Indication as worded in the recordListing only. Not a model-specific clearance and carries no indication.Listed as a therapeutic massager (product code ISA, Class I, exempt from 510(k)). Not a clearance, and carries no shockwave indication.
Other marks and claimsNone notedEU class IIb93/42/EEC
Our notes
Where it stands outPublished purchase and lease pricing, which most of this set does not offer.Several interchangeable piezoelectric therapy sources, and published US prices for replacement sources.
What to checkNo FDA number appears on the reseller page.No 510(k), De Novo or PMA record was located. In the US it is listed as a therapeutic massager, and ELvation limits the US intended use to minor aches and pains.

4 further fields have no published figure for either machine.

Chattanooga Intelect Focus Shockwave vs ELvation PiezoWave2T: common questions

What is the difference between the Chattanooga Intelect Focus Shockwave and the ELvation PiezoWave2T?

Both the Chattanooga Intelect Focus Shockwave and the ELvation PiezoWave2T concentrate their energy at a focal point inside tissue, so they are built for the same clinical job and compare fairly. The Chattanooga Intelect Focus Shockwave uses electromagnetic wave generation; the ELvation PiezoWave2T uses piezoelectric. The Chattanooga Intelect Focus Shockwave is described as “Electromagnetic focused”, the ELvation PiezoWave2T as “Focused piezoelectric, direct focusing”.

Which is cheaper, the Chattanooga Intelect Focus Shockwave or the ELvation PiezoWave2T?

Only the Chattanooga Intelect Focus Shockwave has a published purchase figure ($50,176.02 estimate); the ELvation PiezoWave2T's price is not published. Monthly figures: Chattanooga Intelect Focus Shockwave, $1,165 per month; ELvation PiezoWave2T, not published. Prices change and estimates are not quotes, so confirm both in writing.

Are the Chattanooga Intelect Focus Shockwave and the ELvation PiezoWave2T FDA cleared?

FDA records located: for the Chattanooga Intelect Focus Shockwave, an establishment listing only, which is not a clearance; for the ELvation PiezoWave2T, an establishment listing only, which is not a clearance. A record covers one configuration and one indication, and never transfers to another model, so check it against the exact configuration you are quoted.

How do I choose between the Chattanooga Intelect Focus Shockwave and the ELvation PiezoWave2T?

Start with the clinical job, then ask both vendors for the same five things in writing: the exact model, revision, and which accessories are included at that price; contract term, APR, total payments, and the buyout option at the end; handpiece and consumable life, and what a replacement costs; warranty coverage and US service turnaround time; the exact FDA clearance number and the current labelling for the configuration being quoted.

More comparisons

Still deciding?

Talk it through with our equipment team

Tell us about your practice and caseload. We will help you weigh the options and send lease and purchase estimates for the machines we sell.

Request a consultation
↑