- Purchase
- $17,850
Both the Gymna ShockMaster 500 and the BTL-6000 RSWT put their peak energy at the applicator surface, so they are built for the same clinical job and compare fairly. Both use pneumatic wave generation. Only the Gymna ShockMaster 500 has a published purchase figure ($17,850 at one US seller, listed sold out); the BTL-6000 RSWT's price is not published. FDA records located: for the Gymna ShockMaster 500, no record located; for the BTL-6000 RSWT, no record located.
Specs and prices are estimates based on publicly available data as of September 2026. Confirm details with the manufacturer or seller before you buy.
| Specification | RadialGymna ShockMaster 500 | RadialBTL-6000 RSWT |
|---|---|---|
Technology | ||
| Category | Radial pressure wave | Radial pressure wave |
| Wave generation | Pneumaticbuilt-in oil compressor | Pneumaticprojectile-driven applicators |
| Energy fieldWhere the peak energy lands | Peaks at the applicator surface | Peaks at the applicator surface |
| Technology as published | Pneumatic radial | Pneumatic radial |
Energy outputPressure in bar, energy flux density in mJ/mm² and energy per pulse in mJ are different quantities. A figure in one row never stands in for another. | ||
| Pressurebar | 0.3–5 bareffective bar, in 0.1 bar steps | 1.5–6 barElite, with a 10 Hz maximum at 6 bar; the Pro and Easy reach 4 bar |
| FrequencyHz | 0.5–21 Hz35 Hz with V-Actor | 1–22 HzElite; the Pro and Easy run 1–15 Hz |
Depth and treatment fieldFocal depth, penetration and focus volume measure three different things. Compare like with like. | ||
| Maximum penetration | 0–60 mmDeep Impact applicator; 0–40 mm with the beam applicator | Not published |
Applicators and handpiece | ||
| Applicators and transmitters | Beam, Deep Impact and D-Actor 20 mmstandard set; more are optional | MAGNUM applicator with 9 mm and 15 mm transmittersPro and Elite; the Easy uses the EASY applicator |
| Handpiece life | Revision prompt every 1.25 million shocks4 revisions included | Up to 4 million shocksMAGNUM applicator |
| Applicator weight | About 500 gRSW handpiece | 0.7 kgMAGNUM; the EASY applicator is 1.1 kg |
| Preset protocols | Over 90pre-programmed settings | 22Pro and Elite, plus user-defined; 7 on the Easy |
Size and setup | ||
| Unit weight | 65 kg (≈ 143.3 lb)complete; the latest datasheet says 72 kg | 7 kg (≈ 15.4 lb)main unit, all tiers |
| Dimensions | 102 × 58 × 57 cmH × L × W, on its trolley | 320 × 190 × 280 mmmain unit, W × H × D |
| Configuration | Trolley unit with a built-in oil compressor7-inch touchscreen | Portable tabletop unitoptional trolley |
| Other published details | Two handpiece connectionssoft start ramps up from 1 bar; software updates by USB | Easy, Pro and Elite tiers8.4-inch touchscreen on the Elite, 5.7-inch on the Pro, LED display on the Easy |
Price and buying | ||
| Purchase price | $17,850at one US seller, listed sold out | Not publicly listed |
| Monthly lease | Not publicly listed | Not publicly listed |
| Sales and service | US direct channel unclearno US dealer listed; the nearest is in Ontario, Canada | No clearly named US sales or service entity |
Regulatory recordRecord types and numbers exactly as located. A record covers one configuration and one indication, and never transfers to another product. | ||
| FDA record located | None located | None located |
Our notes | ||
| Where it stands out | Very large preset protocol library. | A tiered lineup that fits several budget levels. |
| What to check | US direct channel is unclear and no FDA number was found. | No clearly named US sales or service entity on the pages reviewed. |
11 further fields have no published figure for either machine.
Both the Gymna ShockMaster 500 and the BTL-6000 RSWT put their peak energy at the applicator surface, so they are built for the same clinical job and compare fairly. Both use pneumatic wave generation. The Gymna ShockMaster 500 is described as “Pneumatic radial”, the BTL-6000 RSWT as “Pneumatic radial”.
Only the Gymna ShockMaster 500 has a published purchase figure ($17,850 at one US seller, listed sold out); the BTL-6000 RSWT's price is not published. Prices change and estimates are not quotes, so confirm both in writing.
FDA records located: for the Gymna ShockMaster 500, no record located; for the BTL-6000 RSWT, no record located. A record covers one configuration and one indication, and never transfers to another model, so check it against the exact configuration you are quoted.
Start with the clinical job, then ask both vendors for the same five things in writing: the exact model, revision, and which accessories are included at that price; contract term, APR, total payments, and the buyout option at the end; handpiece and consumable life, and what a replacement costs; warranty coverage and US service turnaround time; the exact FDA clearance number and the current labelling for the configuration being quoted.
Still deciding?
Tell us about your practice and caseload. We will help you weigh the options and send lease and purchase estimates for the machines we sell.