Both the EMS Swiss DolorClast Classic and the Zimmer enPuls 2.0 / Pro put their peak energy at the applicator surface, so they are built for the same clinical job and compare fairly. The EMS Swiss DolorClast Classic uses pneumatic wave generation; the Zimmer enPuls 2.0 / Pro uses electromagnetic ballistic. Neither publishes a purchase price, so both need a written quote. FDA records located: for the EMS Swiss DolorClast Classic, PMA P050004 (Chronic proximal plantar fasciitis in patients 18 or older, with symptoms for 6 months or more and a history of unsuccessful conservative therapy); for the Zimmer enPuls 2.0 / Pro, no record located.
Specs and prices are estimates based on publicly available data as of September 2026. Confirm details with the manufacturer or seller before you buy.
| Specification | RadialEMS Swiss DolorClast Classic | RadialZimmer enPuls 2.0 / Pro |
|---|---|---|
Technology | ||
| Category | Radial pressure wave | Radial pressure wave |
| Wave generation | Pneumaticexternal compressed-air supply | Electromagnetic ballisticcompressor-free |
| Energy fieldWhere the peak energy lands | Peaks at the applicator surface | Peaks at the applicator surface |
| Technology as published | Pneumatic radial, external compressor | Compressor-free electromagnetic ballistic radial |
Energy outputPressure in bar, energy flux density in mJ/mm² and energy per pulse in mJ are different quantities. A figure in one row never stands in for another. | ||
| Energy flux densitymJ/mm² | Up to 0.18 mJ/mm² | Not published |
| Energy per pulsemJ | Not published | 60–185 mJin 10 mJ steps; Zimmer compares the range to 1–5 bar |
| Pressurebar | 1–4 bar | Not published |
| FrequencyHz | Up to 15 Hz | 1–22 Hz |
Applicators and handpiece | ||
| Applicators and transmitters | Handpiece with a 15 mm applicatoras described in the FDA summary | 6, 15 and 25 mm headschanged without tools; the enPuls 2.0 ships two 15 mm heads |
| Handpiece life | Over 500,000 impulsesvalidated in the 2007 FDA summary | 2 million pulseshandpiece warranty |
| Applicator weight | Not published | About 1.87 lbhandpiece, with cable |
| Preset protocols | Not published | 7 presetscustomizable |
Size and setup | ||
| Unit weight | Not published | 6 lb (≈ 2.7 kg)enPuls 2.0, without handpiece |
| Dimensions | Not published | 12.7 × 9.3 × 5.1 inenPuls 2.0, L × W × H; the enPuls Pro is 7.9 × 13.8 × 11.8 in |
| Configuration | Console with manometer and LCDruns from an external compressed-air supply; compressor and cart are optional accessories | Compressor-free, light chassisfoot switch triggers pulses |
| Other published details | EMS's original radial devicesold since 1999 | 7-inch touchscreen on the enPuls 2.0, 12-inch on the enPuls Prothe Pro weighs 8.4 lb, runs two handpieces and adds a visual analogue pain scale |
Price and buying | ||
| Purchase price | Not publicly listed | Not publicly listed |
| Monthly lease | Not publicly listed | Not publicly listed |
| Warranty and guarantees | Not published | 2 million-pulse handpiece warranty |
| Sales and service | Through EMSnot listed on EMS's US website; confirm it is still sold | Strong direct US service channelZimmer MedizinSystems, Irvine, California |
Regulatory recordRecord types and numbers exactly as located. A record covers one configuration and one indication, and never transfers to another product. | ||
| FDA record located | PMA P050004 | None located |
| Indication as worded in the record | Chronic proximal plantar fasciitis in patients 18 or older, with symptoms for 6 months or more and a history of unsuccessful conservative therapy | No record to quote |
| Decision date | May 2007 | Not stated |
Our notes | ||
| Where it stands out | A PMA approval, FDA's most stringent premarket pathway, covering chronic proximal plantar fasciitis. | Strong direct US service channel and a light chassis. |
| What to check | An older design that needs an external compressor. EMS's US website lists only its DolorClast Radial and Focused, so confirm the Classic is still sold before quoting. | No device-specific 510(k) number was found. |
7 further fields have no published figure for either machine.
Both the EMS Swiss DolorClast Classic and the Zimmer enPuls 2.0 / Pro put their peak energy at the applicator surface, so they are built for the same clinical job and compare fairly. The EMS Swiss DolorClast Classic uses pneumatic wave generation; the Zimmer enPuls 2.0 / Pro uses electromagnetic ballistic. The EMS Swiss DolorClast Classic is described as “Pneumatic radial, external compressor”, the Zimmer enPuls 2.0 / Pro as “Compressor-free electromagnetic ballistic radial”.
Neither publishes a purchase price, so both need a written quote. Prices change and estimates are not quotes, so confirm both in writing.
FDA records located: for the EMS Swiss DolorClast Classic, PMA P050004 (Chronic proximal plantar fasciitis in patients 18 or older, with symptoms for 6 months or more and a history of unsuccessful conservative therapy); for the Zimmer enPuls 2.0 / Pro, no record located. A record covers one configuration and one indication, and never transfers to another model, so check it against the exact configuration you are quoted.
Start with the clinical job, then ask both vendors for the same five things in writing: the exact model, revision, and which accessories are included at that price; contract term, APR, total payments, and the buyout option at the end; handpiece and consumable life, and what a replacement costs; warranty coverage and US service turnaround time; the exact FDA clearance number and the current labelling for the configuration being quoted.